Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Request Permissions
Google Scholar
Right arrow Articles by Suzuki, M.
Right arrow Articles by Suzuki, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suzuki, M.
Right arrow Articles by Suzuki, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

J. Biochem, 1990, Vol. 108, No. 1 92-98
© 1990 Japanese Biochemical Society


research-article

High-Performance Liquid Chromatography—Mass Spectrometry of Glycosphingolipids: II. Application to Neutral Glycolipids and Monosialogangliosides1

Minoru Suzuki, Tamio Yamakawa and Akemi Suzuki

Department of Membrane Biochemistry, The Tokyo Metropolitan Institute of Medical Science Bunkyo-ku, Tokyo 113

We previously reported a method of high-performance liquid chromatography-fast atom bombardment mass spectrometry (HPLC/FAB/MS) for the structural characterization of molecular species of GlcCer and IV3 ßGal-Gb4 Cer [M. Suzuki et al. (1989) J. Biochem. 105, 829–833]. In this paper, we report a modification of this HPLC/FAB/MS method, which was used for the separation and characterization of neutral glycosphingolipids (GlcCer, LacCer, Gb3Cer, Gb4Cer, and IV3{alpha}GalNAc-Gb4Cer) and monosialogangliosides [GM3(NeuAc or NeuGc), GM2 (NeuAc or NeuGc), and GM1 (NeuAc or NeuGc)]. Mixtures of the purified neutral glycolipids and monosialogangliosides were subjected to HPLC on a silica gel column, with programmed elution with isopropanol-n-hexane-water, with or without ammonium hydroxide. In order to obtain mass spectra and mass chromatograms of individual components, effluent from the HPLC column was mixed with a methanol solution of triethanolamine, which was used as the matrix for the FAB ionization, and one-thirtieth of the effluent mixture was introduced into a mass spectrometer through a frit interface. A mixture of the five neutral glycolipids, 5 µg of each, gave five peaks on a mass chromatogram obtained by monitoring of the corresponding major pseudo-molecular ions. A mixture of the six monosialogangliosides, 5 µg of each, gave six peaks on a mass chromatogram obtained by monitoring of the major pseudo-molecular ions, indicating that GM3, GM2, and GM1 were clearly separated, and that separation due to differences in sialic acid species was also achieved. In the mass spectra of the neutral glycolipids and monosialogangliosides, pseudo-molecular ions and fragment ions due to the elimination of sugar moieties were clearly detected. We applied this method to the analysis of a mixture of neutral glycolipids isolated from human erythrocytes and that of a mixture of monosialogangliosides isolated from the liver of a mouse, GlcCer, LacCer, Gb3Cer, Lc3Cer, Gb4Cer, and nLc4Cer and GM3(NeuAc), GM3(NeuGc), GM2(NeuGc), and GM1(NeuGc) being detected, respectively. This method is of great advantage for the structural characterization of neutral glycolipids and monosialogangliosides, especially when they are in mixtures and/or in small amounts. The method will also be quite promising for other neutral glycolipids and gangliosides with the establishment of suitable separation conditions on HPLC.

1This work was supported in part by Grants-in-Aid from the Ministry of Education, Science and Culture of Japan, and a grant from the Mitsubishi Foundation.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.